• Diameter: 2-1/2 in
• CBM: 1/4 NPT
• Pressure Range: 0-200 PSI
• Dual scale in PSI (black) and in kPa (red)
• Working Temperature: -18 to 60 °C
• Accuracy: ± 1.6 % of the full scale
Material(s):
• Housing: 304 Stainless steel
• Crystal: Acrylic
• Bourdon Tube: Phosphorous bronze
• Movement: Brass with highly polished bearing surfaces
• Connection: Brass
• Excellent resistance to corrosion
• High quality pressure gauge with glycerine which prolongs the service life of the pressure gauge
• Gycerine prevents needle vibrations, protects the mechanism and facilitates pressure reading
• Calibration certifications available upon request
INSTALLATION TIP
For vertical position only: fill port is on the top
When excessive vibrations are present, a pressure snubber should be used in order to maximize the useful life of the gauge
• Working pressure should be limited to 60 % of the dial maximum pressure
• Where no sharp fluctuations occur, it should be limited to 90 % of the dial maximum pressure
• Pneumatic and hydraulic systems, air tools, hydraulic presses, air compressors, machine tools
• Diameter: 2-1/2 in
• CBM: 1/4 NPT
• Pressure Range: 0-200 PSI
• Dual scale in PSI (black) and in kPa (red)
• Working Temperature: -18 to 60 °C
• Accuracy: ± 1.6 % of the full scale
Material(s):
• Housing: 304 Stainless steel
• Crystal: Acrylic
• Bourdon Tube: Phosphorous bronze
• Movement: Brass with highly polished bearing surfaces
• Connection: Brass
• Excellent resistance to corrosion
• High quality pressure gauge with glycerine which prolongs the service life of the pressure gauge
• Gycerine prevents needle vibrations, protects the mechanism and facilitates pressure reading
• Calibration certifications available upon request
INSTALLATION TIP
For vertical position only: fill port is on the top
When excessive vibrations are present, a pressure snubber should be used in order to maximize the useful life of the gauge
• Working pressure should be limited to 60 % of the dial maximum pressure
• Where no sharp fluctuations occur, it should be limited to 90 % of the dial maximum pressure
• Pneumatic and hydraulic systems, air tools, hydraulic presses, air compressors, machine tools